Title: Evaluation of the Comparative Corrosion Resistance Between AKOT Ti Alloy and Ti Gr 7 Alloy

Technical Report ·
DOI:https://doi.org/10.2172/878602· OSTI ID:878602

In its current design, the drip shields for the high-level nuclear waste containers for the Yucca Mountain repository will be mainly made using Ti Gr 7 (R52400). Ti Gr 7 is a highly corrosion resistant alloy, especially because it contains 0.15% palladium (Pd). The goal of this study was to determine whether an AKOT low-Pd (0.01%) titanium alloy would have a similar corrosion resistance than the more expensive Ti Gr 7 in environments that could be related to the performance of the drip shield. The focus of this testing program was on the susceptibility of the alloys to localized corrosion. Therefore, only artificially creviced specimens were used.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
878602
Report Number(s):
UCRL-TR-214248; TRN: US0602417
Country of Publication:
United States
Language:
English