Title: Beam Aborts in PEP-II Rings and Lingering Drift Chamber Currents

Technical Report ·
DOI:https://doi.org/10.2172/833114· OSTI ID:833114

The BABAR detector at SLAC was designed to study CP-violation in B-meson decays from electron-positron collisions in the PEP-II electron-positron storage rings. Background radiation in the High Energy Ring (HER) and Low Energy Ring (LER) of PEP-II has the potential to damage the sensitive equipment in the BABAR detector. As a result, the beams in the HER and LER can be aborted to prevent such damage. In the span of a few microseconds, the HER and LER currents drop from, for example, 1450 micro Amps and 2300 micro Amps, respectively, to zero. At this time the voltage in the Drift Chamber is rapidly ramped down from a potential of 1930 V to a safe potential of 800 V, thus we would expect the currents in the Drift Chamber to quickly go to zero once the beams are aborted. However, we observe an average 15 second delay in the measured time it takes for all current in the Drift Chamber to fall below 1 micro Amp. This delay has been hypothesized as an instrumentation issue and not as a physical phenomenon. The specific sources of this error are still not completely known, but analysis suggests that it results from the interplay of the CAEN High Voltage supplies and the EPICS system and/or limitations within those systems.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Science (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
833114
Report Number(s):
SLAC-TN-04-060; TRN: US0406569
Resource Relation:
Other Information: PBD: 3 Sep 2004
Country of Publication:
United States
Language:
English

Similar Records

The Abort Kicker System for the PEP-II Storage Rings at SLAC.
Technical Report · Fri Jun 20 00:00:00 EDT 2003 · OSTI ID:833114

The PEP-II abort kicker system
Conference · Tue Jul 01 00:00:00 EDT 1997 · OSTI ID:833114

Vacuum Performance and Beam Life Time in the PEP-II Storage Rings
Technical Report · Wed Aug 21 00:00:00 EDT 2002 · OSTI ID:833114