skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A Benchmarking Analysis for Five Radionuclide Vadose Zone Models (Chain, Multimed{_}DP, Fectuz, Hydrus, and Chain 2D) in Soil Screening Level Calculations

Conference ·
OSTI ID:828636

Five vadose zone models with different degrees of complexity (CHAIN, MULTIMED{_}DP, FECTUZ, HYDRUS, and CHAIN 2D) were selected for use in radionuclide soil screening level (SSL) calculations. A benchmarking analysis between the models was conducted for a radionuclide ({sup 99}Tc) release scenario at the Las Cruces Trench Site in New Mexico. Sensitivity of three model outputs to the input parameters were evaluated and compared among the models. The three outputs were peak contaminant concentrations, time to peak concentrations at the water table, and time to exceed the contaminants maximum critical level at a representative receptor well. Model parameters investigated include soil properties such as bulk density, water content, soil water retention parameters and hydraulic conductivity. Chemical properties examined include distribution coefficient, radionuclide half-life, dispersion coefficient, and molecular diffusion. Other soil characteristics, such as recharge rate, also were examined. Model sensitivity was quantified in the form of sensitivity and relative sensitivity coefficients. Relative sensitivities were used to compare the sensitivities of different parameters. The analysis indicates that soil water content, recharge rate, saturated soil water content, and soil retention parameter, {beta}, have a great influence on model outputs. In general, the results of sensitivities and relative sensitivities using five models are similar for a specific scenario. Slight differences were observed in predicted peak contaminant concentrations due to different mathematical treatment among models. The results of benchmarking and sensitivity analysis would facilitate the model selection and application of the model in SSL calculations.

Research Organization:
Dynamac Corporation, 3601 Oakridge Boulevard, Ada, OK (US); ManTech Environmental Research Services Corporation 919 Kerr Research Drive, P.O. Box 1198, Ada, OK; U.S. EPA, Office of Research and Development National Risk Management Research Laboratory Subsurface Protection and Remediation Division 919 Kerr Research Drive, P.O. Box 1198, Ada, OK (US)
Sponsoring Organization:
none (US)
OSTI ID:
828636
Resource Relation:
Conference: Waste Management 2002 Symposium, Tucson, AZ (US), 02/24/2002--02/28/2002; Other Information: PBD: 26 Feb 2002
Country of Publication:
United States
Language:
English