ANALYSIS OF DOSE RATES DURING REPLACEMENT OF MANIPULATORS IN THE FFTF INTERIM EXAMINATION & MAINTENANCE (IEM) CELL
Replacement of a master-slave manipulator in the Interim Examination and Maintenance Cell at the Fast Flux Test Facility was carried out in August 2001. This operation created a 178-mm opening in the thick concrete wall of the hot cell. To aid in radiological work planning, dose rates outside the penetration in the wall were predicted using MCNP{trademark} photon transport calculations. The predicted dose rate was 7.7 mrem/h, which was reasonably close to the value of 10.4 mrem/h inferred from measurements.
- Research Organization:
- Fluor Hanford, Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Management (EM) (US)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 820826
- Report Number(s):
- HNF-9843-FP, Rev.0; TRN: US0400627
- Resource Relation:
- Other Information: PBD: 23 Jan 2002
- Country of Publication:
- United States
- Language:
- English
Similar Records
Calculation of dose rates during replacement of the 3CL seal tube in the FFTF IEM cell
FFTF/IEM (Fast Flux Test Facility/Interim Examination and Maintenance) cell fuel pin weighing system: Remote maintenance design considerations
Large remote manipulator operating and maintenance experience at the IEM (Interim Examination and Maintenance) Cell
Technical Report
·
Wed Nov 12 00:00:00 EST 1997
·
OSTI ID:820826
FFTF/IEM (Fast Flux Test Facility/Interim Examination and Maintenance) cell fuel pin weighing system: Remote maintenance design considerations
Conference
·
Sun Jun 01 00:00:00 EDT 1986
·
OSTI ID:820826
Large remote manipulator operating and maintenance experience at the IEM (Interim Examination and Maintenance) Cell
Conference
·
Wed Oct 01 00:00:00 EDT 1986
·
OSTI ID:820826