Title: FINAL REPORT ENHANCED GEOTHERMAL SYSTEMS TECHNOLOGY PHASE II ANIMAS VALLEY, NEW MEXICO

Technical Report ·
DOI:https://doi.org/10.2172/820539· OSTI ID:820539

Final Technical Report covering siting, permitting, and drilling two geothermal temperature gradient holes. This report provides a summary of geotechnical and geophysical data that led to the siting, drilling, and completion of 2 temperature gradient holes in the geothermal anomaly at Lightning Dock Known Geothermal Resource Area in the Animas Valley of New Mexico. Included in this report is a summary of institutional factors and data defining the well drilling process and acquiring drilling permits. Data covering the results of the drilling and temperature logging of these two holes are provided. The two gradient holes were sited on federal geothermal leases owned by Lightning Dock Geothermal, Inc. and both holes were drilled into lakebed sediments some distance from the intense shallow geothermal anomaly located in the eastern half of Section 7, Township 25 South, Range 19 West.

Research Organization:
LIGHTNING DOCK GEOTHERMAL INC. (US)
Sponsoring Organization:
USDOE Office of Geothermal Technologies(EE-12) (US)
DOE Contract Number:
FC07-01ID14203
OSTI ID:
820539
Report Number(s):
DOE/ID/14203; TRN: US200405%%32
Resource Relation:
Other Information: PBD: 29 Dec 2003
Country of Publication:
United States
Language:
English