Title: Testing and plugging power plant heat exchangers

Conference ·
OSTI ID:81439
 [1]
  1. Expando Seal Tools, Inc., Montgomeryville, PA (United States)

Heat Exchanger tubes fail for any number of reasons including but certainly not limited to the cumulative effects of corrosion, erosion, thermal stress and fatigue. This presentation will attempt to identify the most common techniques for determining which tubes are leaking and then introduce the products in use to plug the leaking tubes. For the sake of time I will limit the scope of this presentation to include feedwater heaters and secondary system heat exchangers such as Hydrogen Coolers, Lube Oil Coolers, and nuclear Component Cooling Water, Emergency Cooling Water, Regenerative Heat Recovery heat exchangers.

Research Organization:
US Department of Energy (USDOE), Washington DC (United States); Korea Electric Power Corp. (KEPCO), Seoul (Korea, Republic of)
OSTI ID:
81439
Report Number(s):
CONF-941089-Vol.1; ON: DE95011612; TRN: 95:016768
Resource Relation:
Conference: US-Korea electric power generation seminar mission, Seoul (Korea, Republic of), 24-28 Oct 1994; Other Information: PBD: [1994]; Related Information: Is Part Of US-Korea Electric Power Generation Seminar Mission: Proceedings, Volume 1; Harris, J.J. [USDOE Deputy Assistant Secretary, Washington, DC (United States). Office of Science and Technology Policy]; PB: 459 p.
Country of Publication:
United States
Language:
English