This report summarizes the early results of the post irradiation examination of the 30 GWd/MT MOX Average Power Test Capsules (numbers 3 and 10). The purpose of this preliminary examination is to document and monitor the progress of the MOX Average Power Test Irradiation. The capsules and their fuel pins were found to be in excellent condition. Measurement of the fission gas release fraction (about 1.50 to 2.26%), preliminary fuel stack gamma scan measurements, and preliminary fuel pin diameter measurements indicate that the fuel is behaving as expected.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC05-00OR22725
OSTI ID:
814226
Report Number(s):
ORNL/MD/LTR-208; TRN: US0304233
Resource Relation:
Other Information: PBD: 14 Feb 2001
Country of Publication:
United States
Language:
English