242-A Evaporator quality assurance plan. Revision 2
Abstract
The purpose of this quality assurance project plan (Plan) is to provide requirements for activities pertaining to sampling, shipping, and analyses associated with candidate feed tank samples for the 242-A Evaporator project. The purpose of the 242-A Evaporator project is to reduce the volume of aqueous waste in the Double Shell Tank (DST) System and will result in considerable savings to the disposal of mixed waste. The 242-A Evaporator feed stream originates from DSTs identified as candidate feed tanks. The 242-A Evaporator reduces the volume of aqueous waste contained in DSTs by boiling off water and sending the condensate (called process condensate) to the Liquid Effluent Retention Facility (LEPF) storage basin where it is stored prior to treatment in the Effluent Treatment Facility (ETF). The objective of this quality assurance project plan is to provide the planning, implementation, and assessment of sample collection and analysis, data issuance, and validation activities for the candidate feed tanks.
- Authors:
- Publication Date:
- Research Org.:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Org.:
- USDOE, Washington, DC (United States)
- OSTI Identifier:
- 80952
- Report Number(s):
- WHC-SD-WM-QAPP-009-Rev.2
ON: DE95012575; TRN: 95:016312
- DOE Contract Number:
- AC06-87RL10930
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: 4 May 1995
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 05 NUCLEAR FUELS; EVAPORATORS; QUALITY ASSURANCE; HANFORD RESERVATION; RADIOACTIVE WASTE PROCESSING; RADIOACTIVE WASTE FACILITIES; VOLUME; LIQUID WASTES; PROGRAM MANAGEMENT
Citation Formats
Basra, T S. 242-A Evaporator quality assurance plan. Revision 2. United States: N. p., 1995.
Web. doi:10.2172/80952.
Basra, T S. 242-A Evaporator quality assurance plan. Revision 2. United States. https://doi.org/10.2172/80952
Basra, T S. 1995.
"242-A Evaporator quality assurance plan. Revision 2". United States. https://doi.org/10.2172/80952. https://www.osti.gov/servlets/purl/80952.
@article{osti_80952,
title = {242-A Evaporator quality assurance plan. Revision 2},
author = {Basra, T S},
abstractNote = {The purpose of this quality assurance project plan (Plan) is to provide requirements for activities pertaining to sampling, shipping, and analyses associated with candidate feed tank samples for the 242-A Evaporator project. The purpose of the 242-A Evaporator project is to reduce the volume of aqueous waste in the Double Shell Tank (DST) System and will result in considerable savings to the disposal of mixed waste. The 242-A Evaporator feed stream originates from DSTs identified as candidate feed tanks. The 242-A Evaporator reduces the volume of aqueous waste contained in DSTs by boiling off water and sending the condensate (called process condensate) to the Liquid Effluent Retention Facility (LEPF) storage basin where it is stored prior to treatment in the Effluent Treatment Facility (ETF). The objective of this quality assurance project plan is to provide the planning, implementation, and assessment of sample collection and analysis, data issuance, and validation activities for the candidate feed tanks.},
doi = {10.2172/80952},
url = {https://www.osti.gov/biblio/80952},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu May 04 00:00:00 EDT 1995},
month = {Thu May 04 00:00:00 EDT 1995}
}