Title: IMPEDANCE MEASUREMENT SETUP FOR HIGHER-ORDER MODE STUDIES IN NLC ACCELERATING STRUCTURES WITH THE WIRE METHOD

Abstract

Dipole modes are the main cause of transverse emittance dilution in the Japanese Linear Collider/Next Linear Collider (JLC/NLC). A diagnostic setup has been built in order to investigate them. The method is based on using a coaxial wire to excite and measure electromagnetic modes of accelerating structures. This method can offer a more efficient and less expensive procedure than the ASSET facility. Initial measurements have been made and are presented in this paper.

Authors:
Publication Date:
Research Org.:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Org.:
USDOE Office of Science (US)
OSTI Identifier:
801788
Report Number(s):
SLAC-PUB-9472
TRN: US0204748
DOE Contract Number:  
AC03-76SF00515
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 19 Sep 2002
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; DILUTION; DIPOLES; IMPEDANCE; LINEAR COLLIDERS

Citation Formats

Baboi, Nicoleta. IMPEDANCE MEASUREMENT SETUP FOR HIGHER-ORDER MODE STUDIES IN NLC ACCELERATING STRUCTURES WITH THE WIRE METHOD. United States: N. p., 2002. Web. doi:10.2172/801788.
Baboi, Nicoleta. IMPEDANCE MEASUREMENT SETUP FOR HIGHER-ORDER MODE STUDIES IN NLC ACCELERATING STRUCTURES WITH THE WIRE METHOD. United States. https://doi.org/10.2172/801788
Baboi, Nicoleta. 2002. "IMPEDANCE MEASUREMENT SETUP FOR HIGHER-ORDER MODE STUDIES IN NLC ACCELERATING STRUCTURES WITH THE WIRE METHOD". United States. https://doi.org/10.2172/801788. https://www.osti.gov/servlets/purl/801788.
@article{osti_801788,
title = {IMPEDANCE MEASUREMENT SETUP FOR HIGHER-ORDER MODE STUDIES IN NLC ACCELERATING STRUCTURES WITH THE WIRE METHOD},
author = {Baboi, Nicoleta},
abstractNote = {Dipole modes are the main cause of transverse emittance dilution in the Japanese Linear Collider/Next Linear Collider (JLC/NLC). A diagnostic setup has been built in order to investigate them. The method is based on using a coaxial wire to excite and measure electromagnetic modes of accelerating structures. This method can offer a more efficient and less expensive procedure than the ASSET facility. Initial measurements have been made and are presented in this paper.},
doi = {10.2172/801788},
url = {https://www.osti.gov/biblio/801788}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Sep 19 00:00:00 EDT 2002},
month = {Thu Sep 19 00:00:00 EDT 2002}
}