Confirmation Run of the DWPF SRAT Cycle Using the Sludge-Only Flowsheet with Tank 40 Radioactive Sludge and Frit 200 in the Shielded Cells Facility
Abstract
Several basic data reports have been issued concerning the recent demonstration of the Defense Waste Processing Facility (DWPF) Sludge Receipt and Adjustment Tank (SRAT) Cycle and Slurry Mix Evaporator (SME) Cycle, conducted at the Savannah River Technology Center (SRTC). The SRTC demonstration was completed using the DWPF ''Sludge-Only'' flowsheet with washed Tank 40 sludge slurry (Sludge Batch 2 or Macrobatch 3) in the Shielded Cells facility. The DWPF ''Sludge-Only'' flowsheet calls for processing radioactive sludge slurry using nitric acid, concentrated formic acid, and frit 200.
- Authors:
- Publication Date:
- Research Org.:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Org.:
- US Department of Energy (US)
- OSTI Identifier:
- 800727
- Report Number(s):
- WSRC-TR-2002-00076
TRN: US0205367
- DOE Contract Number:
- AC09-96SR18500
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: PBD: 29 Aug 2002
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; EVAPORATORS; FLOWSHEETS; SAVANNAH RIVER PLANT; SLUDGES; RADIOACTIVE WASTE PROCESSING; PERFORMANCE TESTING; VITRIFICATION
Citation Formats
Fellinger, T L. Confirmation Run of the DWPF SRAT Cycle Using the Sludge-Only Flowsheet with Tank 40 Radioactive Sludge and Frit 200 in the Shielded Cells Facility. United States: N. p., 2002.
Web. doi:10.2172/800727.
Fellinger, T L. Confirmation Run of the DWPF SRAT Cycle Using the Sludge-Only Flowsheet with Tank 40 Radioactive Sludge and Frit 200 in the Shielded Cells Facility. United States. https://doi.org/10.2172/800727
Fellinger, T L. 2002.
"Confirmation Run of the DWPF SRAT Cycle Using the Sludge-Only Flowsheet with Tank 40 Radioactive Sludge and Frit 200 in the Shielded Cells Facility". United States. https://doi.org/10.2172/800727. https://www.osti.gov/servlets/purl/800727.
@article{osti_800727,
title = {Confirmation Run of the DWPF SRAT Cycle Using the Sludge-Only Flowsheet with Tank 40 Radioactive Sludge and Frit 200 in the Shielded Cells Facility},
author = {Fellinger, T L},
abstractNote = {Several basic data reports have been issued concerning the recent demonstration of the Defense Waste Processing Facility (DWPF) Sludge Receipt and Adjustment Tank (SRAT) Cycle and Slurry Mix Evaporator (SME) Cycle, conducted at the Savannah River Technology Center (SRTC). The SRTC demonstration was completed using the DWPF ''Sludge-Only'' flowsheet with washed Tank 40 sludge slurry (Sludge Batch 2 or Macrobatch 3) in the Shielded Cells facility. The DWPF ''Sludge-Only'' flowsheet calls for processing radioactive sludge slurry using nitric acid, concentrated formic acid, and frit 200.},
doi = {10.2172/800727},
url = {https://www.osti.gov/biblio/800727},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Aug 29 00:00:00 EDT 2002},
month = {Thu Aug 29 00:00:00 EDT 2002}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.