Annual INTEC Groundwater Monitoring Report for Group 5 - Snake River Plain Aquifer (2001)
This report describes the monitoring activities conducted and presents the results of groundwater sampling and water-level measurements from October 2000 to September 2001. Groundwater samples were initially collected from 41 wells from the Idaho Nuclear Technology and Engineering Center and the Central Facilities Area and analyzed for iodine- 129, strontium-90, tritium, gross alpha, gross beta, technetium-99, uranium isotopes, plutonium isotopes, neptunium-237, gamma spectrometry, and mercury. Samples from 41 wells were collected in April and May 2001. Additional sampling was conducted in August 2001 and included in two CFA production wells, the CFA point of compliance for the production wells, one well was previously sampled and five additional monitoring wells. Water-level measurements were taken from in the Idaho Nuclear Technology and Engineering Center, Central Facilities Area, and the area south of Central Facilities Area to evaluate groundwater flow directions. Water-level measurements indicated groundwater flow to the south-southwest from the Idaho Nuclear Technology and Engineering Center.
- Research Organization:
- Idaho National Lab. (INL), Idaho Falls, ID (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Management (EM) (US)
- DOE Contract Number:
- AC07-99ID13727
- OSTI ID:
- 794383
- Report Number(s):
- DOE/ID-10930; TRN: US0201144
- Resource Relation:
- Other Information: PBD: 28 Feb 2002
- Country of Publication:
- United States
- Language:
- English
Similar Records
Results of 2001 Groundwater Sampling in Support of Conditional No Longer Contained-In Determination for the Snake River Plain Aquifer in the Vicinity of the INTEC at the INEEL
Results of 2001 Groundwater Sampling in Support of Conditional No Longer Contained-In Determination for the Snake River Plain Aquifer in the Vicinity of the Idaho Nuclear Technology and Engineering Center
Related Subjects
AQUIFERS
COMPLIANCE
IODINE
MERCURY
MONITORING
NEPTUNIUM 237
PLUTONIUM ISOTOPES
PRODUCTION
SAMPLING
SNAKE RIVER PLAIN
STRONTIUM 90
TECHNETIUM 99
TRITIUM
URANIUM ISOTOPES
GROUND WATER
GROUNDWATER
WELLS
IODINE-129
STRONTIUM-90
GROSS ALPHA
GROSS BETA
TECHNETIUM-99
URANIUM
PLUTONIUM
NEPTUNIUM-237
AMERICIUM-241
GAMMA SPECTROMETRY