Four-Point Bending Strength Testing of Pultruded Fiberglass Composite Wind Turbine Blade Sections
- MDZ Consulting
The ultimate strength of the PS Enterprises pultruded blade section was experimentally determined under four-point bending at the National Renewable Energy Laboratory. Thirteen 8-foot long full-scale blade segments were individually tested to determine their maximum moment carrying capability. Three airfoil-bending configurations were tested: high- and low-pressure skin buckling, and low pressure skin buckling with foam interior reinforcement. Maximum strain was recorded for each sample on the compressive and tensile surfaces of each test blade. Test data are compared to the results of three analytical buckling prediction methods. Based on deviations from the linear strain versus load curve, data indicate a post-buckling region. High-pressure side buckling occurred sooner than low-pressure side buckling. The buckling analyses were conservative for both configurations, but high-pressure side buckling in particular was substantially under-predicted. Both high- and low-pressure buckling configurations had very similar failure loads. These results suggests that a redundant load path may be providing strength to the section in the post-buckling region, making the onset of panel buckling a poor predictor of ultimate strength for the PS Enterprises pultrusion.
- Research Organization:
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC36-99GO10337
- OSTI ID:
- 786407
- Report Number(s):
- NREL/CP-500-30565; TRN: AH200136%%98
- Resource Relation:
- Conference: AWEA's WINDPOWER 2001 Conference, Washington, DC (US), 06/04/2001--06/07/2001; Other Information: PBD: 10 Jul 2001
- Country of Publication:
- United States
- Language:
- English
Similar Records
Economic competitiveness of pultruded fiber composites for wind turbine applications
Local buckling and failure of pultruded fiber-reinforced plastic beams