Conceptual Methods for Decontamination and Decommissioning, Size Reduction, and Disposal of the DWPF Melter and Components
This report identifies potential methods for the disassembly, size reduction, and decontamination of large DWPF equipment. It specifically targets the DWPF Melter. Methods found to work on the melter should be easily applied to other equipment, as the melter is the most complex large-scale equipment that must be processed. It is also likely to be the most contaminated component as it could contain up to 16,000 pounds of HLW glass in it when it is shut down. This report also evaluates methods, equipment, and techniques that may be used. It also discusses possible dismantlement sequences that could be used as well as issues that need to be addressed. In addition, past experiences in dismantling and inspection of various ceramic-lined melters will be discussed.
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 782041
- Report Number(s):
- WSRC-TR-2001-00248; TRN: US0103086
- Resource Relation:
- Other Information: PBD: 15 Jun 2001
- Country of Publication:
- United States
- Language:
- English
Similar Records
Yield Stress Reduction of DWPF Melter Feed Slurries
The Behavior and Effects of the Noble Metals in the DWPF Melter System