skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Solvent Extraction External Radiation Stability Testing

Technical Report ·
DOI:https://doi.org/10.2172/773130· OSTI ID:773130

Personnel irradiated a number of samples of calixarene-based solvent. Analysis of these samples indicated that measurable loss of the calixarene occurred at very high doses (-16 Mrad). No measurable loss of the Cs-7SB modifier occurred at equivalent doses. The primary degradation product, 4-sec-butylphenol, observed during analysis of the samples came from degradation of the modifier. Also, TOA proved more susceptible to damage than the other components of the solvent. The total degradation of the solvent proved relatively minor. The consistent solvent performance, as indicated by the measured D Cs values, after exposure at high total doses serves as evidence of the relatively low degree of degradation of the solvent components. Additional tests employing internal irradiation of solvents with both simulants and SRS tank waste will be completed by the end of March 2001 to provide confirmation of the results presented herein.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC09-96SR18500
OSTI ID:
773130
Report Number(s):
WSRC-TR-2000-00413; TRN: US0100022
Resource Relation:
Other Information: PBD: 5 Jan 2001
Country of Publication:
United States
Language:
English