A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter
Abstract
A new Compton polarimeter is built on the CEBAF Hall A electron beam line. Performances of 10% resolution and 1% calibration are required for the photon calorimeter of this polarimeter. This calorimeter is built with lead tungstate scintillators coming from the CMS electromagnetic calorimeter R&D. Beam tests of this detector have been made using the tagged photon beam line at MAMI, Mainz, and a resolution of 1.76%+2.75%/v+0.41%/E has been measured.
- Authors:
-
- CEA Saclay, France
- Institut fur Kernphysik, Mainz, Germany
- Publication Date:
- Research Org.:
- Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
- Sponsoring Org.:
- USDOE Office of Energy Research (ER) (US)
- OSTI Identifier:
- 767062
- Report Number(s):
- JLAB-PHY-00-20; DOE/ER/40150-1770
TRN: US0005541
- DOE Contract Number:
- AC05-84ER40150
- Resource Type:
- Journal Article
- Journal Name:
- Nucl Instrum Meth A 443 (2000), 231-237
- Additional Journal Information:
- Other Information: Submitted to Nucl Instrum Meth A 443 (2000), 231-237; PBD: 1 May 2000
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS; CALIBRATION; CALORIMETERS; ELECTRON BEAMS; LEAD TUNGSTATES; PHOTON BEAMS; PHOTONS; POLARIMETERS; RESOLUTION
Citation Formats
Neyret, D, Pussieux, T, Auger, T, Baylac, M, Burtin, E, Cavata, C, Chipaux, R, Escoffier, S, Falletto, N, Jardillier, J, Kerhoas, S, Lhuillier, D, Marie, F, Veyssiere, C, Ahrens, J, Beck, R, and Lang, M. A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter. United States: N. p., 2000.
Web. doi:10.1016/S0168-9002(99)01092-X.
Neyret, D, Pussieux, T, Auger, T, Baylac, M, Burtin, E, Cavata, C, Chipaux, R, Escoffier, S, Falletto, N, Jardillier, J, Kerhoas, S, Lhuillier, D, Marie, F, Veyssiere, C, Ahrens, J, Beck, R, & Lang, M. A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter. United States. https://doi.org/10.1016/S0168-9002(99)01092-X
Neyret, D, Pussieux, T, Auger, T, Baylac, M, Burtin, E, Cavata, C, Chipaux, R, Escoffier, S, Falletto, N, Jardillier, J, Kerhoas, S, Lhuillier, D, Marie, F, Veyssiere, C, Ahrens, J, Beck, R, and Lang, M. 2000.
"A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter". United States. https://doi.org/10.1016/S0168-9002(99)01092-X. https://www.osti.gov/servlets/purl/767062.
@article{osti_767062,
title = {A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter},
author = {Neyret, D and Pussieux, T and Auger, T and Baylac, M and Burtin, E and Cavata, C and Chipaux, R and Escoffier, S and Falletto, N and Jardillier, J and Kerhoas, S and Lhuillier, D and Marie, F and Veyssiere, C and Ahrens, J and Beck, R and Lang, M},
abstractNote = {A new Compton polarimeter is built on the CEBAF Hall A electron beam line. Performances of 10% resolution and 1% calibration are required for the photon calorimeter of this polarimeter. This calorimeter is built with lead tungstate scintillators coming from the CMS electromagnetic calorimeter R&D. Beam tests of this detector have been made using the tagged photon beam line at MAMI, Mainz, and a resolution of 1.76%+2.75%/v+0.41%/E has been measured.},
doi = {10.1016/S0168-9002(99)01092-X},
url = {https://www.osti.gov/biblio/767062},
journal = {Nucl Instrum Meth A 443 (2000), 231-237},
number = ,
volume = ,
place = {United States},
year = {Mon May 01 00:00:00 EDT 2000},
month = {Mon May 01 00:00:00 EDT 2000}
}
Other availability