skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter

Abstract

A new Compton polarimeter is built on the CEBAF Hall A electron beam line. Performances of 10% resolution and 1% calibration are required for the photon calorimeter of this polarimeter. This calorimeter is built with lead tungstate scintillators coming from the CMS electromagnetic calorimeter R&D. Beam tests of this detector have been made using the tagged photon beam line at MAMI, Mainz, and a resolution of 1.76%+2.75%/v+0.41%/E has been measured.

Authors:
; ; ; ; ; ; ; ; ; ; ; ; ;  [1]; ; ;  [2]
  1. CEA Saclay, France
  2. Institut fur Kernphysik, Mainz, Germany
Publication Date:
Research Org.:
Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
Sponsoring Org.:
USDOE Office of Energy Research (ER) (US)
OSTI Identifier:
767062
Report Number(s):
JLAB-PHY-00-20; DOE/ER/40150-1770
TRN: US0005541
DOE Contract Number:  
AC05-84ER40150
Resource Type:
Journal Article
Journal Name:
Nucl Instrum Meth A 443 (2000), 231-237
Additional Journal Information:
Other Information: Submitted to Nucl Instrum Meth A 443 (2000), 231-237; PBD: 1 May 2000
Country of Publication:
United States
Language:
English
Subject:
72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS; CALIBRATION; CALORIMETERS; ELECTRON BEAMS; LEAD TUNGSTATES; PHOTON BEAMS; PHOTONS; POLARIMETERS; RESOLUTION

Citation Formats

Neyret, D, Pussieux, T, Auger, T, Baylac, M, Burtin, E, Cavata, C, Chipaux, R, Escoffier, S, Falletto, N, Jardillier, J, Kerhoas, S, Lhuillier, D, Marie, F, Veyssiere, C, Ahrens, J, Beck, R, and Lang, M. A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter. United States: N. p., 2000. Web. doi:10.1016/S0168-9002(99)01092-X.
Neyret, D, Pussieux, T, Auger, T, Baylac, M, Burtin, E, Cavata, C, Chipaux, R, Escoffier, S, Falletto, N, Jardillier, J, Kerhoas, S, Lhuillier, D, Marie, F, Veyssiere, C, Ahrens, J, Beck, R, & Lang, M. A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter. United States. https://doi.org/10.1016/S0168-9002(99)01092-X
Neyret, D, Pussieux, T, Auger, T, Baylac, M, Burtin, E, Cavata, C, Chipaux, R, Escoffier, S, Falletto, N, Jardillier, J, Kerhoas, S, Lhuillier, D, Marie, F, Veyssiere, C, Ahrens, J, Beck, R, and Lang, M. 2000. "A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter". United States. https://doi.org/10.1016/S0168-9002(99)01092-X. https://www.osti.gov/servlets/purl/767062.
@article{osti_767062,
title = {A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter},
author = {Neyret, D and Pussieux, T and Auger, T and Baylac, M and Burtin, E and Cavata, C and Chipaux, R and Escoffier, S and Falletto, N and Jardillier, J and Kerhoas, S and Lhuillier, D and Marie, F and Veyssiere, C and Ahrens, J and Beck, R and Lang, M},
abstractNote = {A new Compton polarimeter is built on the CEBAF Hall A electron beam line. Performances of 10% resolution and 1% calibration are required for the photon calorimeter of this polarimeter. This calorimeter is built with lead tungstate scintillators coming from the CMS electromagnetic calorimeter R&D. Beam tests of this detector have been made using the tagged photon beam line at MAMI, Mainz, and a resolution of 1.76%+2.75%/v+0.41%/E has been measured.},
doi = {10.1016/S0168-9002(99)01092-X},
url = {https://www.osti.gov/biblio/767062}, journal = {Nucl Instrum Meth A 443 (2000), 231-237},
number = ,
volume = ,
place = {United States},
year = {Mon May 01 00:00:00 EDT 2000},
month = {Mon May 01 00:00:00 EDT 2000}
}