Title: Rapid sampling using 3M membrane technology. Innovative Technology Summary Report

S&T Accomplishment Report ·
DOI:https://doi.org/10.2172/766928· OSTI ID:766928

The 3M-Empore (TM) High Performance Extraction Disks have become the solid-phase extraction industry standard for meeting U.S. EPA requirements for water analysis of various analytes, including Cs, Sr, Ra, Tc, and U as well as several non-radionuclides including Pb, Hg, Sb, and As. These disks utilize adsorbing particles embedded in a membrane, greatly simplifying radiometric sampling and analysis. After liquid samples are passed through the disks, the disks are placed onto planchets or into liquid-scintillation vials for radiometric counting. For field use they are available in Rapid Liquid Sampler (RLS) form; this is a rugged, color-coded, disposable plastic holder (2-1/8' diameter), which readily adapts Rad Disks to commercial devices such as the Isco field sampler and 3M attended field sampler.

Research Organization:
Savannah River Site, Aiken, SC (US); Argonne National Lab., IL (US); Paducah Gaseous Diffusion Plant, Paducah, KY (US); West Valley Demonstration Project, West Valley, NY (US); General Electric Storage Facility, Morris, IL (US)
Sponsoring Organization:
USDOE Office of Science and Technology (OST) (EM-50) (US)
OSTI ID:
766928
Report Number(s):
DOE/EM-0501; OST/TMS ID 1514; OST/TMS ID 1514; TRN: US200210%%146
Resource Relation:
Other Information: PBD: 1 Jan 2000; PBD: 1 Jan 2000
Country of Publication:
United States
Language:
English