The Next Linear Collider comprises about 5,000 traveling wave sections, each manufactured from about 200 precision machined cells. Each cell in a section has a different shape. Measuring the shape of a cell with sufficient accuracy takes approximately of 1/2 hour using conventional CMM techniques. This is because many points on the interior of the cell must be measured to assure the cell will be resonant at the proper monopole (accelerating) frequency and the proper dipole frequency. On the other hand these frequencies can be measured to the required accuracy of a fraction of a megahertz in a few seconds using either a modern microwave network analyzer or a specialized system designed just for measuring these cell resonances. The microwave measurement in effect does an integral over the whole surface contour to find the net error in desired frequency. In order to avoid damaging cells it is ideal to use a non-contacting RF test apparatus with non-contacting shorts and choke joints on either side of the cell. The complex geometry of the proposed damped detuned cell structures makes it difficult to obtain high Q with non-contacting shorting plates[1]. It is still possible to get sub-megahertz resolution by measuring phase rather than amplitude at resonance and using reference cavities for calibration. It is assumed that the system will be highly automated with automatic cell handling and data recording.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
765011
Report Number(s):
SLAC-PUB-8620; TRN: US0004991
Resource Relation:
Other Information: PBD: 14 Sep 2000
Country of Publication:
United States
Language:
English

Similar Records

A damped detuned structure for the next linear collider
Conference · Sun Sep 01 00:00:00 EDT 1996 · OSTI ID:765011

Enhanced Machine-Learning Flow for Microwave-Sensing Systems to Detect Contaminants in Food
Journal Article · Tue Jul 18 00:00:00 EDT 2023 · TBD · OSTI ID:765011

Analysis and Control of Wakefields in X-Band Crab Cavities for Compact Linear Collider
Journal Article · Wed Apr 25 00:00:00 EDT 2012 · Nuclear Instruments and Methods in Physics Research, Section A · OSTI ID:765011