Title: Analysis of In-Situ Vibration Monitoring for End-Point Detection of CMP Planarization Processes

Conference ·
OSTI ID:7243

This paper details the analysis of vibration monitoring for end-point control in oxide CMP processes. Two piezoelectric accelerometers were integrated onto the backside of a stainless steel polishing head of an IPEC 472 polisher. One sensor was placed perpendicular to the carrier plate (vertical) and the other parallel to the plate (horizontal). Wafers patterned with metal and coated with oxide material were polished at different speeds and pressures. Our results show that it is possible to sense a change in the vibration signal over time during planarization of oxide material on patterned wafers. The horizontal accelerometer showed more sensitivity to change in vibration amplitude compared to the vertical accelerometer for a given polish condition. At low carrier and platen rotation rates, the change in vibration signal over time at fixed frequencies decreased approximately ½ - 1 order of magnitude (over the 2 to 10 psi polish pressure ranges). At high rotation speeds, the vibration signal remained essentially constant indicating that other factors dominated the vibration signaL These results show that while it is possible to sense changes in acceleration during polishing, more robust hardware and signal processing algorithms are required to ensure its use over a wide range of process conditions.

Research Organization:
Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
7243
Report Number(s):
SAND99-1183C; ON: DE00007243
Resource Relation:
Conference: SPIE Symposium on Microelectronics Manufacturing Technologies; Edinburgh, Scotland; 05/19-21/1999
Country of Publication:
United States
Language:
English

Similar Records

End-point process development for low-volume, high reliability tungsten CMP
Conference · Mon Dec 01 00:00:00 EST 1997 · OSTI ID:7243

High G MEMS integrated accelerometer
Conference · Tue Dec 31 00:00:00 EST 1996 · OSTI ID:7243

Chemical Mechanical Planarization (CMP) Metrology for 45/32 nm Technology Generations
Journal Article · Wed Sep 26 00:00:00 EDT 2007 · AIP Conference Proceedings · OSTI ID:7243