Title: Evaluation of zeolite mixtures for decontaminating high-activity-level water at the Three Mile Island Unit 2 Nuclear Power Station

Conference ·
OSTI ID:7156280

Mixtures of Linde Ionsiv IE-96 and Ionsiv A-51 were evaluated for use in the Submerged Demineralizer System (SDS) that was installed at the Three Mile Island Unit 2 Nuclear Power Station to decontaminate approx. 2780 m/sup 3/ of high-activity-level water. The original SDS flowsheet was conservatively designed for removal of cesium and strontium and would have required the use of approx. 60 SDS columns. Mixed zeolite tests were made on a 10/sup -5/ scale and indicated that the appropriate ratio of IE-96/A-51 was 3/2. A mathematical model was used to predict the performance of the mixed zeolite columns in the SDS configuration and with the intended method of operation. Actual loading results were similar to those predicted for strontium and better than those predicted for cesium. The number of SDS columns needed to process the HALW was reduced to approx. 10. 6 references, 4 figures, 2 tables.

Research Organization:
Oak Ridge National Lab., TN (USA); Du Pont de Nemours (E.I.) and Co., Aiken, SC (USA). Savannah River Lab.
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-84OR21400; AC09-76SR00001
OSTI ID:
7156280
Report Number(s):
DP-MS-84-49; CONF-8406123-1; IAEA-TC-518/4; ON: DE84012564
Resource Relation:
Conference: IAEA Technical Committee meeting on inorganic ion exchangers and absorbents for chemical processing in the nuclear fuel cycle, Vienna, Austria, 12-15 Jun 1984; Other Information: Portions are illegible in microfiche products
Country of Publication:
United States