skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Local fault tolerance of metal fuel

Technical Report ·
DOI:https://doi.org/10.2172/711877· OSTI ID:711877

This IFR technical memorandum presents a review of the potential initiators of fuel failure in metal fuel and a preliminary evaluation of the consequences of failure and the potential for propagation within a fuel assembly. Lines of defense against initiation and propagation are identified and some discussed in detail including appropriate supportive conclusions from oxide fuel assessments. The ongoing supporting fuel element test program is described and areas requiring further analytical or experimental effort are identified. Based on the extensive experience in EBR-II with uranium-fissium fuel, and the differences between the properties of metallic and oxide fuel constitutents, superior local faults tolerance of ternary alloy fuel is anticipated. 34 refs.

Research Organization:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
W-31-109-ENG-38
OSTI ID:
711877
Report Number(s):
ANL-IFR-37; ON: TI86026203
Resource Relation:
Other Information: PBD: Feb 1986
Country of Publication:
United States
Language:
English