skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Integrated low emissions cleanup system for direct coal fueled turbines (Moving bed, fluid bed contactor/ceramic filter)

Technical Report ·
DOI:https://doi.org/10.2172/7045424· OSTI ID:7045424

The United States Department of Energy, Morgantown Energy Research Center (DOE/METC), is sponsoring the development of direct coal-fired turbine power plants as part of their Heat Engines program. A major technical challenge remaining for the development of the direct coal-fired turbine is high-temperature combustion gas cleaning to meet environmental standards for sulfur oxides and particulate emissions, as well as to provide acceptable turbine life. The Westinghouse Electric Corporation, Science Technology Center, is evaluating two Integrated Low Emissions Cleanup (ILEC) concepts that have been configured to meet this technical challenge: a baseline ceramic barrier filter ILEC concept, and a fluidized bed ILEC concept. These ILEC concepts simultaneously control sulfur, particulate, and alkali contaminants in the high-pressure combustion gases at turbine inlet temperatures up to 2300{degrees}F. This document reports the status of a program in the seventeenth quarter to develop this ILEC technology for direct coal-fired turbine power plants.

Research Organization:
Westinghouse Electric Corp., Pittsburgh, PA (United States). Science and Technology Center
Sponsoring Organization:
USDOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC21-87MC24257
OSTI ID:
7045424
Report Number(s):
DOE/MC/24257-T18; ON: DE92017791
Country of Publication:
United States
Language:
English