A high-energy, low-inductance, low prefire rate, low trigger jitter, high-voltage, pulsed-power supply was needed to drive the gas discharge in the Antares laser power amplifier. This report describes the design and testing of a Marx generator that meets these requirements, the development and testing of a high-capacity spark gap, and the selection of suitable capacitors and resistors.