skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Selection of support structure materials for irradiation experiments in the HFIR (High Flux Isotope Reactor) at temperatures up to 500 degrees C

Technical Report ·
DOI:https://doi.org/10.2172/6973221· OSTI ID:6973221

The key factor in the design of capsules for irradiation of test specimens in the High Flux Isotope Reactor at preselected temperatures up to 500{degree}C utilizing nuclear heating is a narrow gas-filled gap which surrounds the specimens and controls the transfer of heat from the specimens through the wall of a containment tube to the reactor cooling water. Maintenance of this gap to close tolerances is dependent on the characteristics of the materials used to support the specimens and isolate them from the water. These support structure materials must have low nuclear heating rates, high thermal conductivities, and good dimensional stabilities under irradiation. These conditions are satisfied by certain aluminum alloys. One of these alloys, a powder metallurgy product containing a fine dispersion of aluminum oxide, is no longer manufactured. A new alloys of this type, with the trade name DISPAL, is determined to be a suitable substitute. 23 refs., 13 figs., 3 tabs.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
DOE/ER
DOE Contract Number:
AC05-84OR21400
OSTI ID:
6973221
Report Number(s):
ORNL/TM-11378; ON: DE90010228; TRN: 90-010902
Country of Publication:
United States
Language:
English