Title: MIT extraction method for measuring average subchannel axial velocities in reactor assemblies

Technical Report ·
DOI:https://doi.org/10.2172/6942337· OSTI ID:6942337

The MIT extraction method for obtaining flow split data for individual subchannels is described in detail. An analysis of the method is presented which shows that isokinetic values of the subchannel flow rates are obtained directly even though the method is non-isokinetic. Time saving methods are discussed for obtaining the average value of the interior region flow split parameter. An analysis of the method at low bundle flow rates indicates that there is no inherent low flow rate limitation on the method and suggests a way to obtain laminar flow split data.

Research Organization:
Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)
DOE Contract Number:
AS02-76ET37240
OSTI ID:
6942337
Report Number(s):
DOE/ET/37240-80TR; TRN: 81-003834
Country of Publication:
United States
Language:
English