Title: Low level signal data acquisition for the MFTF-B superconducting magnet system

Conference ·
OSTI ID:6894886

Acquisition of low level signals from sensors mounted on the superconducting magnets in the Tandem Mirror Fusion Test Facility (MFTF-B) impose very strict requirements on the magnet signal conditioning and data acquisition system. Of the various types of sensors required, thermocouples and strain gages produce very low level outputs. These low level outputs must be accurately measured in the harsh environment of slowly varying magnetic fields, cryogenic temperatures, high vacuum, 80 kV pulse power, 60 Hz, 17 MHz and 28, 35, and 56 GHz electrical noise and possible neutron radiation. Successful measurements require careful attention to grounding, shielding, signal handling and processing in the data acquisition system. The magnet instrumentation system provides a means of effectively measuring both low level signals and high level signals from all types of sensors. Various methods involved in the design and implementation of the system for signal conditioning and data gathering will be presented.

Research Organization:
Lawrence Livermore National Lab., CA (USA)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
6894886
Report Number(s):
UCRL-90191; CONF-8404138-1; ON: DE84011047
Resource Relation:
Conference: 8. national engineering symposium of the Mexican American Engineering Society, Albuquerque, NM, USA, 11 Apr 1984; Other Information: Portions are illegible in microfiche products
Country of Publication:
United States
Language:
English