Electrical grounding, shielding, and isolation for the MFTF-B plasma diagnostic system
Conference
·
OSTI ID:6845719
The electrical grounding, shielding, and isolation of plasma diagnostics on the Mirror Fusion Test Facility (MFTF-B) is a key part of the overall design. The Electromagnetic Interference (EMI) environment in which the Plasma Diagnostics System (PDS) will be required to operate is very harsh. The electrical grounding and shielding design which is being implemented to cope with this environment follows one which has been used successfully on the Tandem Mirror Experiment (TMX). Details of the MFTF-B plasma diagnostics facility, equipment grounding, shielding and isolation, and the cabling system are described in this paper.
- Research Organization:
- Lawrence Livermore National Lab., CA (USA)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 6845719
- Report Number(s):
- UCRL-89224; CONF-831203-150; ON: DE84012539
- Resource Relation:
- Conference: 10. symposium on fusion engineering, Philadelphia, PA, USA, 5 Dec 1983; Other Information: Portions are illegible in microfiche products
- Country of Publication:
- United States
- Language:
- English