Title: Corrosion of aluminum cladding under optimized water conditions

Technical Report ·
DOI:https://doi.org/10.2172/6844838· OSTI ID:6844838

Experience at SRS, ORNL, BNL, and Georgia Institute of Technology involving irradiated aluminum clad fuel and target elements, as well as studies of non-irradiated aluminum indicate that some types of aluminum assemblies can be kept in a continually well-deionized water atmosphere for up to 25 years without problems. SRS experience ranges from 2.75 years for the L-1.1 charge kept in deionized D[sub 2]O[sup 1] to greater than 10 years for assemblies stored in the Receiving Basin for Off-site Fuel (RBOF)[sup 2]. Experience at Georgia Institute of Technology reactor in Atlanta yielded the longest value of 25 years without problems. The common denominators in all of the reports is that the water is continually deionized to approximately 2 M[Omega] (2 [times] 10[sup 6]ohms) resistivity and the containers for the water are stainless steel or other non-porous material. This resistivity value is equivalent to a value of 0.5 micromhos or microSiemens conductivity and is reagent grade II quality water.[sup 3] 4 tabs, 26 refs.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
6844838
Report Number(s):
RRD-RTS-920119; ON: DE93004958
Country of Publication:
United States
Language:
English