Title: Hybrid staging of a Lysholm positive displacement engine with two Westinghouse two stage impulse Curtis turbines

Technical Report ·
DOI:https://doi.org/10.2172/6837667· OSTI ID:6837667

The University of California at Berkeley has tested and modeled satisfactorly a hybrid staged Lysholm engine (positive displacement) with a two stage Curtis wheel turbine. The system operates in a stable manner over its operating range (0/1-3/1 water ratio, 120 psia input). Proposals are made for controlling interstage pressure with a partial admission turbine and volume expansion to control mass flow and pressure ratio for the Lysholm engine.

Research Organization:
California Univ., Berkeley (USA). Coll. of Engineering
DOE Contract Number:
AT03-80ET27252
OSTI ID:
6837667
Report Number(s):
DOE/ET/27252-T2; ON: DE84013693
Resource Relation:
Other Information: Portions are illegible in microfiche products. Thesis
Country of Publication:
United States