Conceptual design report of a refuse-fired steam plant
This is a conceptual design report for the installation of a refuse-fired boiler to produce steam. The refuse, mostly paper waste, would come from two adjacent facilities, Sandia National Laboratories, Livermore and Lawrence Livermore National Laboratory. The new steam plant, to be located at SNLL, would produce close to 100% of the steam requirements at SNLL. Unfortunately it does not have an attractive payback.
- Research Organization:
- Sandia National Lab. (SNL-CA), Livermore, CA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC04-76DP00789
- OSTI ID:
- 6811308
- Report Number(s):
- SAND-82-8235; ON: DE82021074
- Country of Publication:
- United States
- Language:
- English
Similar Records
Solar fuels and chemicals system design study (ammonia/nitric acid production process). Volume 2. Conceptual design. Final report
Estimates of costs of conventional coal fired steam production plants. [With one and four 250,000 lb. /h boilers producing steam at 650 psig and 750/sup 0/F]
Tacoma Refuse Fired Combustor Study for the City of Tacoma, Washington
Technical Report
·
Sun Jun 01 00:00:00 EDT 1986
·
OSTI ID:6811308
Estimates of costs of conventional coal fired steam production plants. [With one and four 250,000 lb. /h boilers producing steam at 650 psig and 750/sup 0/F]
Technical Report
·
Wed Jun 01 00:00:00 EDT 1977
·
OSTI ID:6811308
Tacoma Refuse Fired Combustor Study for the City of Tacoma, Washington
Technical Report
·
Wed Mar 01 00:00:00 EST 1978
·
OSTI ID:6811308
Related Subjects
20 FOSSIL-FUELED POWER PLANTS
29 ENERGY PLANNING
POLICY AND ECONOMY
REFUSE-FUELED POWER PLANTS
CAPITALIZED COST
DESIGN
ENVIRONMENTAL IMPACTS
OPERATING COST
DUAL-PURPOSE POWER PLANTS
SAFETY
SANDIA LABORATORIES
COST
NATIONAL ORGANIZATIONS
POWER PLANTS
THERMAL POWER PLANTS
US AEC
US DOE
US ERDA
US ORGANIZATIONS
200103* - Fossil-Fueled Power Plants- Waste-Fueled Systems
299000 - Energy Planning & Policy- Unconventional Sources & Power Generation
29 ENERGY PLANNING
POLICY AND ECONOMY
REFUSE-FUELED POWER PLANTS
CAPITALIZED COST
DESIGN
ENVIRONMENTAL IMPACTS
OPERATING COST
DUAL-PURPOSE POWER PLANTS
SAFETY
SANDIA LABORATORIES
COST
NATIONAL ORGANIZATIONS
POWER PLANTS
THERMAL POWER PLANTS
US AEC
US DOE
US ERDA
US ORGANIZATIONS
200103* - Fossil-Fueled Power Plants- Waste-Fueled Systems
299000 - Energy Planning & Policy- Unconventional Sources & Power Generation