Title: Design, construction, operation and evaluation of a prototype culm combustion boiler/heater unit. Final design of prototype unit

Abstract

A final design of a prototype anthracite culm combustion boiler has been accomplished under Phase I of DOE Contract ET-78-C-01-3269. The prototype boiler has been designed to generate 20,000 pounds per hour of 150 psig saturated steam using low Btu (4000 Btu per pound) anthracite culm as a fuel. This boiler will be located at the industrial park of the Shamokin Area Industrial Corporation (SAIC). This program is directed at demonstrating the commercial viability of anthracite culm fueled FBC steam generation systems.

Publication Date:
Research Org.:
Curtiss-Wright Corp., Wood-Ridge, NJ (USA). Power Systems Div.; Dorr-Oliver, Inc., Stamford, CT (USA); Stone and Webster Engineering Corp., New York (USA)
OSTI Identifier:
6782310
Report Number(s):
DOE/ET/12307-T1; CW-WR-78-036
DOE Contract Number:  
AC21-78ET12307
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
01 COAL, LIGNITE, AND PEAT; 42 ENGINEERING; CULM; FLUIDIZED-BED COMBUSTION; DEMONSTRATION PLANTS; FLUIDIZED-BED COMBUSTORS; DESIGN; ANTHRACITE; DIAGRAMS; SPECIFICATIONS; BLACK COAL; CARBONACEOUS MATERIALS; CHEMICAL REACTIONS; COAL; COMBUSTION; COMBUSTORS; ENERGY SOURCES; FOSSIL FUELS; FUELS; MATERIALS; MINERAL WASTES; OXIDATION; SOLID WASTES; THERMOCHEMICAL PROCESSES; WASTES; 014000* - Coal, Lignite, & Peat- Combustion; 010800 - Coal, Lignite, & Peat- Waste Management; 421000 - Engineering- Combustion Systems

Citation Formats

. Design, construction, operation and evaluation of a prototype culm combustion boiler/heater unit. Final design of prototype unit. United States: N. p., 1980. Web. doi:10.2172/6782310.
. Design, construction, operation and evaluation of a prototype culm combustion boiler/heater unit. Final design of prototype unit. United States. https://doi.org/10.2172/6782310
. 1980. "Design, construction, operation and evaluation of a prototype culm combustion boiler/heater unit. Final design of prototype unit". United States. https://doi.org/10.2172/6782310. https://www.osti.gov/servlets/purl/6782310.
@article{osti_6782310,
title = {Design, construction, operation and evaluation of a prototype culm combustion boiler/heater unit. Final design of prototype unit},
author = {},
abstractNote = {A final design of a prototype anthracite culm combustion boiler has been accomplished under Phase I of DOE Contract ET-78-C-01-3269. The prototype boiler has been designed to generate 20,000 pounds per hour of 150 psig saturated steam using low Btu (4000 Btu per pound) anthracite culm as a fuel. This boiler will be located at the industrial park of the Shamokin Area Industrial Corporation (SAIC). This program is directed at demonstrating the commercial viability of anthracite culm fueled FBC steam generation systems.},
doi = {10.2172/6782310},
url = {https://www.osti.gov/biblio/6782310}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Oct 01 00:00:00 EDT 1980},
month = {Wed Oct 01 00:00:00 EDT 1980}
}