Title: Neutron ion temperature measurement

Conference ·
OSTI ID:6766633

One important use of fusion product diagnostics is in the determination of the deuterium ion temperature from the magnitude of the 2.5 MeV d(d,n)/sup 3/He neutron emission. The detectors, calibration methods, and limitations of this technique are reviewed here with emphasis on procedures used at PPPL. In most tokamaks, the ion temperature deduced from neutrons is in reasonable agreement with the ion temperature deduced by other techniques.

Research Organization:
Princeton Univ., NJ (USA). Plasma Physics Lab.
DOE Contract Number:
AC02-76CH03073
OSTI ID:
6766633
Report Number(s):
PPPL-2395; CONF-860902-4; ON: DE87005629
Resource Relation:
Conference: Course and workshop on basic and advanced fusion plasma diagnostic techniques, Varenna, Italy, 3 Sep 1986; Other Information: Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted
Country of Publication:
United States
Language:
English