Title: Effects of the reactor-coolant pumps during a small-break loss-of-coolant accident

Conference ·
OSTI ID:6661843

TRAC-PD2 calculations indicate that more coolant mass remains in the system when the reactor coolant pumps are left in operation following a small cold-leg break. The analyses were performed for a Westinghouse plant (Zion-1) to help determine whether to trip the pumps at high-pressure injection initiation (the present operator directive), to trip the pumps at some later time in the transient, or to leave the pumps running indefinitely. The loop seals' behavior and the system refill characteristics primarily determined the results. 9 figures.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6661843
Report Number(s):
LA-UR-82-1717; CONF-830103-10; ON: DE82018456
Resource Relation:
Conference: 2. international topical meeting on nuclear thermalhydraulics, Santa Barbara, CA, USA, 11 Jan 1982; Other Information: Portions of document are illegible
Country of Publication:
United States
Language:
English