Title: Trace gas concentrator FY 1995 summary report

Technical Report ·
DOI:https://doi.org/10.2172/663386· OSTI ID:663386

This report summarizes the accomplishments of the Trace Gas Concentrator Technology Demonstration Project during FY 1995 and through February 1996. The purpose of the activity was to demonstrate proof of principle of a system that concentrates airborne substances (e.g., chemical agents, explosives, narcotics and their precursors, and pollutants) to aid in their detection. A comprehensive computer model (initiated in FY 1994) was developed for the theoretical prediction of the fluid dynamics and mass concentration of the trace gas concentrator. The gas test stand has been installed and checked out. An automated computer data acquisition system has been installed and connected to the concentrator test stand. The data acquisition system is needed to record gas and mechanical operations.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE Assistant Secretary for Nuclear Energy, Washington, DC (United States)
DOE Contract Number:
AC05-96OR22464
OSTI ID:
663386
Report Number(s):
ORNL/TM-13235; ON: DE98003601; TRN: AHC29818%%223
Resource Relation:
Other Information: PBD: May 1996