Title: Progress in ETA-II magnetic field alignment using stretched wire and low energy electron beam techniques

Conference ·
OSTI ID:6630962

Flux line alignment of the solenoidal focus magnets used on the ETA-II linear induction accelerator is a key element leading to a reduction of beam corkscrew motion. Two techniques have been used on the ETA-II accelerator to measure and establish magnet alignment. A low energy electron beam has been used to directly map magnetic field lines, and recent work has utilized a pulsed stretched wire technique to measure magnet tilts and offsets with respect to a reference axis. This paper reports on the techniques used in the ETA-II accelerator alignment, and presents results from those measurements which show that accelerator is magnetically aligned to within {approximately}{plus minus}200 microns. 3 refs., 8 figs.

Research Organization:
Lawrence Livermore National Lab., CA (USA)
Sponsoring Organization:
USDOD
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
6630962
Report Number(s):
UCRL-103780; CONF-9009123-21; ON: DE91000421
Resource Relation:
Conference: Linear accelerator conference, Albuquerque, NM (USA), 9-14 Sep 1990
Country of Publication:
United States
Language:
English