Task completion report for investigating why output signal-variable values differ from their output component-parameter values in test problem MST2
Signal-variable values and their component-parameter values differ in an end-of-timestep edit to the TRCOUT and TRCGRF files because signal variables have beginning-of-timestep values, and component parameters have end-of-timestep values. Oscillatory divergence in the MST2 standard test problem after 9000 s occurs because of TRAC-P`s numerical evaluation at a 1000 material Courant number. The magnitude of that divergence has diminished by a factor of 3.5 from Version 5.3.01 to 5.4.15 and by a factor of 25 from Version 5.4.15 to 5.4.28. That divergence can be eliminated by evaluating MST2 with a maximum material Courant number of 500.