Title: Design and performance of the Georgia Tech Aquatic Center photovoltaic system. Final report

Technical Report ·
DOI:https://doi.org/10.2172/656881· OSTI ID:656881

A building-integrated DC PV array has been constructed on the Georgia Tech campus. The array is mounted on the roof of the Georgia Tech Aquatic Center (GTAC), site of the aquatic events during the 1996 Paralympic and Olympic Games in Atlanta. At the time of its construction, it was the world`s largest roof-mounted photovoltaic array, comprised of 2,856 modules and rates at 342 kW. This section describes the electrical and physical layout of the PV system, and the associated data acquisition system (DAS) which monitors the performance of the system and collects measurements of several important meteorological parameters.