Title: High-precision isotopic analysis of nanogram quantities of plutonium

Technical Report ·
DOI:https://doi.org/10.2172/6509034· OSTI ID:6509034

A surface ionization-diffusion-type ionization source that uses a rhenium filament overplated with platinum has been developed and optimized for 0.5- to 2-ng plutonium samples. This source is capable of measuring the /sup 240/Pu//sup 239/Pu atom ratio in nuclear-test-debris samples to 0.15% precision and accuracy at the 95% confidence level.

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6509034
Report Number(s):
LA-10013-MS; ON: DE85001525
Resource Relation:
Other Information: Portions are illegible in microfiche products. Original copy available until stock is exhausted
Country of Publication:
United States
Language:
English