High resolution, large area, high energy x-ray tomography
Conference
·
OSTI ID:646433
An x-ray tomography system is being developed for high resolution inspection of large objects. The goal is to achieve 25 micron resolution over object sizes that are tens of centimeters in extent. Typical objects will be metal in composition and therefore high energy, few MeV x-rays will be required. A proof-of-principle system with a limited field of view has been developed. Preliminary results are presented.
- Research Organization:
- Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 646433
- Report Number(s):
- UCRL-JC-128429; CONF-970706-; ON: DE98051366
- Resource Relation:
- Conference: Annual meeting of the Society of Photo-Optical Instrumentation Engineers, San Diego, CA (United States), 27 Jul - 1 Aug 1997; Other Information: PBD: 1 Aug 1997
- Country of Publication:
- United States
- Language:
- English
Similar Records
Use of local x-ray computerized tomography for high-resolution, region-of-interest inspection of large ceramic components for engines
Use of local x-ray computerized tomography for high-resolution, region-of-interest inspection of large ceramic components for engines
X-ray Computed Tomography and Stereo-Radiographic Inspection Results of the Office of Emergency Response (NA-42) Test Object
Conference
·
Fri Jan 01 00:00:00 EST 1993
·
OSTI ID:646433
Use of local x-ray computerized tomography for high-resolution, region-of-interest inspection of large ceramic components for engines
Conference
·
Fri Jan 01 00:00:00 EST 1993
·
OSTI ID:646433
X-ray Computed Tomography and Stereo-Radiographic Inspection Results of the Office of Emergency Response (NA-42) Test Object
Technical Report
·
Mon Oct 10 00:00:00 EDT 2005
·
OSTI ID:646433