skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Reevaluation of core damage frequency in light of the occurrence of complex transients at B and W plants

Conference ·
OSTI ID:6417358

This paper presents a unified treatment of ''complex transients'' and core damage events, with the aim of relating the frequencies if the two types of events to each other and to the frequencies of their constituent events. This framework provides a basis for relating the observed frequency of certain transient types to core damage frequency, and deciding whether the occurrence of complex transients means that core damage frequency is higher than it was previously believed to be. 5 refs.

Research Organization:
Brookhaven National Lab., Upton, NY (USA)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
6417358
Report Number(s):
BNL-NUREG-41451; CONF-890405-6; ON: DE88013999
Resource Relation:
Conference: International topical meeting on probability, reliability and safety assessment, Pittsburgh, PA, USA, 2 Apr 1989; Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English