Title: Strength of nonuniformly oxidized PGX graphite

Technical Report ·
DOI:https://doi.org/10.2172/6397111· OSTI ID:6397111

Flexural and tensile tests were performed on PGX graphite oxidized to produce a steep surface oxidation gradient. Companion tensile specimens were oxidized under different conditions to produce uniform oxidation throughout the specimen, and their tensile strength and Young's modulus were measured. The flexural strength, flexural elastic modulus, and tensile strength were reduced much less by surface oxidation than by uniform oxidation. The test data were in good agreement with a simple linear elastic model in which Young's modulus at any point is a function of oxidation burnoff, and the strain at failure is independent of oxidation. The unoxidized interior of the specimens appears unaffected by the surface burnoff and remains able to fulfill its load-bearing function. 18 figures, 8 tables.