Performance of the SLAC Linear Collider klystrons
Conference
·
OSTI ID:6365507
There are now 200 new, high power 5045 klystrons installed on the two-mile Stanford Linear Accelerator. Peak power per klystron averages over 63 MW. Average energy contribution is above 240 MeV per station. Electron beam energy has been measured as high as 53 GeV. Energy instability due to klystron malfunction is less than 0.2%. The installed klystrons have logged over one million operating hours with close to 20,000 klystron hours cumulative operating time between failures. Data are being accumulated on klystron operation and failure modes with failure signatures starting to become apparent. To date, no wholesale failure modes have surfaced that would impair the SLAC Linear Collider (SLC) program.
- Research Organization:
- Stanford Linear Accelerator Center, Menlo Park, CA (USA)
- DOE Contract Number:
- AC03-76SF00515
- OSTI ID:
- 6365507
- Report Number(s):
- SLAC-PUB-4262; CONF-870302-196; ON: DE87010544; TRN: 87-028548
- Resource Relation:
- Conference: Particle accelerator conference, Washington, DC, USA, 16 Mar 1987; Other Information: Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted
- Country of Publication:
- United States
- Language:
- English
Similar Records
Recent performance, lifetime, and failure modes of the 5045 klystron population at SLAC
Recent performance, lifetime, and failure modes of the 5045 klystron population at SLAC
Anomalous electron loading in SLAC 5045 klystron and relativistic klystron input cavities
Conference
·
Sat Aug 01 00:00:00 EDT 1992
·
OSTI ID:6365507
+1 more
Recent performance, lifetime, and failure modes of the 5045 klystron population at SLAC
Conference
·
Sat Aug 01 00:00:00 EDT 1992
·
OSTI ID:6365507
+1 more
Anomalous electron loading in SLAC 5045 klystron and relativistic klystron input cavities
Conference
·
Wed Mar 01 00:00:00 EST 1989
·
OSTI ID:6365507
+2 more
Related Subjects
43 PARTICLE ACCELERATORS
KLYSTRONS
PERFORMANCE
STANFORD LINEAR COLLIDER
COMPUTERIZED CONTROL SYSTEMS
EXPERIMENTAL DATA
FAILURES
LIFETIME
RELIABILITY
ACCELERATOR FACILITIES
ACCELERATORS
CONTROL SYSTEMS
DATA
ELECTRON TUBES
ELECTRONIC EQUIPMENT
EQUIPMENT
INFORMATION
LINEAR ACCELERATORS
MICROWAVE EQUIPMENT
MICROWAVE TUBES
NUMERICAL DATA
430300* - Particle Accelerators- Auxiliaries & Components
KLYSTRONS
PERFORMANCE
STANFORD LINEAR COLLIDER
COMPUTERIZED CONTROL SYSTEMS
EXPERIMENTAL DATA
FAILURES
LIFETIME
RELIABILITY
ACCELERATOR FACILITIES
ACCELERATORS
CONTROL SYSTEMS
DATA
ELECTRON TUBES
ELECTRONIC EQUIPMENT
EQUIPMENT
INFORMATION
LINEAR ACCELERATORS
MICROWAVE EQUIPMENT
MICROWAVE TUBES
NUMERICAL DATA
430300* - Particle Accelerators- Auxiliaries & Components