Title: Single wire drift chamber design

Abstract

This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 ..mu..m rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles.

Authors:
Publication Date:
Research Org.:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
OSTI Identifier:
6317641
Report Number(s):
FNAL-TM-1455
ON: DE87011002
DOE Contract Number:  
AC02-76CH03000
Resource Type:
Technical Report
Resource Relation:
Other Information: Paper copy only, copy does not permit microfiche production. Original copy available until stock is exhausted
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; DRIFT CHAMBERS; DESIGN; ELECTRON DETECTION; PERFORMANCE; SPATIAL RESOLUTION; TIME RESOLUTION; CHARGED PARTICLE DETECTION; DETECTION; MEASURING INSTRUMENTS; MULTIWIRE PROPORTIONAL CHAMBERS; PROPORTIONAL COUNTERS; RADIATION DETECTION; RADIATION DETECTORS; RESOLUTION; TIMING PROPERTIES; 430300* - Particle Accelerators- Auxiliaries & Components

Citation Formats

Krider, J. Single wire drift chamber design. United States: N. p., 1987. Web. doi:10.2172/6317641.
Krider, J. Single wire drift chamber design. United States. https://doi.org/10.2172/6317641
Krider, J. 1987. "Single wire drift chamber design". United States. https://doi.org/10.2172/6317641. https://www.osti.gov/servlets/purl/6317641.
@article{osti_6317641,
title = {Single wire drift chamber design},
author = {Krider, J},
abstractNote = {This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 ..mu..m rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles.},
doi = {10.2172/6317641},
url = {https://www.osti.gov/biblio/6317641}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Mar 30 00:00:00 EST 1987},
month = {Mon Mar 30 00:00:00 EST 1987}
}