The fourteenth Personnel Dosimetry Intercomparison Study (i.e., PDIS 14) was conducted during May 1-5, 1989. A total of 48 organizations (33 from the US and 15 from abroad) participated in PDIS 14. Participants submitted by mail a total of 1,302 neutron and gamma dosimeters for this mixed field study. The type of neutron dosimeter and the percentage of participants submitting that type are as follows: TLD-albedo (40%), direct interaction TLD (22%), track (20%), film (7%), combination (7%), and bubble detectors (4%). The type of gamma dosimeter and the percentage of participants submitting that type are as follows: TLD (84%) and film (16%). Radiation sources used in the six PDIS 14 exposures included {sup 252}Cf moderated by 15-cm D{sub 2}O, {sup 252}Cf moderated by 15-cm polyethylene (gamma-enhanced with {sup 137}Cs), and {sup 238}PuBe. Neutron dose equivalents ranged from 0.44--2.63 mSv and gamma doses ranged from 0. 01-1.85 mSv. One {sup 252}Cf(D{sub 2}O) exposure was performed at a 60{degree} angle of incidence (most performance tests are at perpendicular incidence). The average neutron dosimeter response for this exposure was 70% of that at normal incidence. The average gamma dosimeter response was 96% of that at normal incidence. A total of 70% of individual reported neutron dosimeter measurements were within {plus minus}50% of reference values. If the 0.01 mSv data are omitted, approximately 90% of the individual reported gamma measurements were within {plus minus}50% of reference values. 33 refs., 9 figs., 27 tabs.
- Research Organization:
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
- Sponsoring Organization:
- DOE/ER
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 6282586
- Report Number(s):
- ORNL-6597; ON: DE91004978; TRN: 91-004437
- Country of Publication:
- United States
- Language:
- English
Similar Records
Mixed field peronnel dosimetry: Part 1, High temperature peak characteristics of the reader-annealed TLD-600
Summary and analsysis of the 1986 ORNL personnel dosimetry intercomparison study
Related Subjects
DOSEMETERS
PERFORMANCE TESTING
CALIFORNIUM 252
CESIUM 137
COMPARATIVE EVALUATIONS
DOSE EQUIVALENTS
GAMMA DOSIMETRY
GAMMA SOURCES
NEUTRON DOSIMETRY
NEUTRON SOURCES
PERSONNEL DOSIMETRY
PHOTOGRAPHIC FILM DOSEMETERS
THERMOLUMINESCENT DOSEMETERS
ACTINIDE ISOTOPES
ACTINIDE NUCLEI
ALKALI METAL ISOTOPES
ALPHA DECAY RADIOISOTOPES
BETA DECAY RADIOISOTOPES
BETA-MINUS DECAY RADIOISOTOPES
CALIFORNIUM ISOTOPES
CESIUM ISOTOPES
DOSIMETRY
EVEN-EVEN NUCLEI
HEAVY NUCLEI
ISOTOPES
LUMINESCENT DOSEMETERS
MEASURING INSTRUMENTS
NUCLEI
ODD-EVEN NUCLEI
PARTICLE SOURCES
RADIATION SOURCES
RADIOISOTOPES
TESTING
YEARS LIVING RADIOISOTOPES
440102* - Radiation Instrumentation- Radiation Dosemeters