skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Single PWR spent fuel assembly heat transfer data for computer code evaluations

Technical Report ·
DOI:https://doi.org/10.2172/6263991· OSTI ID:6263991

The descriptions and results of two separate heat transfer tests designed to investigate the dry storage of commercial PWR spent fuel assemblies are presented. Presented first are descriptions and selected results from the Fuel Temperature Test performed at the Engine Maintenance and Disassembly facility on the Nevada Test Site. An actual spent fuel assembly from the Turkey Point Unit Number 3 Reactor with a decay heat level of 1.17 KW, was installed vertically in a test stand mounted canister/liner assembly. The boundary temperatures were controlled and the canister backfill gases were alternated between air, helium and vacuum to investigate the primary heat transfer mechanisms of convection, conduction and radiation. The assembly temperature profiles were experimentally measured using installed thermocouple instrumentation. Also presented are the results from the Single Assembly Heat Transfer Test designed and fabricated by Allied General Nuclear Services, under contract to the Department of Energy, and ultimately conducted by the Pacific Northwest Laboratory. For this test, an electrically heated 15 x 15 rod assembly was used to model a single PWR spent fuel assembly. The electrically heated model fuel assembly permitted various ''decay heat'', levels to be tested; 1.0 KW and 0.5 KW were used for these tests. The model fuel assembly was positioned within a prototypic fuel tube and in turn placed within a double-walled sealed cask. The complete test assembly could be positioned at any desired orientation (horizontal, vertical, and 25/sup 0/ from horizontal for the present work) and backfilled as desired (air, helium, or vacuum). Tests were run for all combinations of ''decay heat,'' backfill, and orientation. Boundary conditions were imposed by temperature controlled guard heaters installed on the cask exterior surface.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
6263991
Report Number(s):
PNL-5571; ON: DE86006322
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted
Country of Publication:
United States