Title: Validation of the RVACS (Reactor Vessel Auxiliary Cooling System)/RACS (Reactor Air Cooling System) model in SASSYS-1

Conference ·
OSTI ID:6260134

The SASSYS-1 LMR systems analysis code contains a model for transient analysis of heat removal by a RVACS (Reactor Vessel Auxiliary Cooling System) or a RACS (Reactor Air Cooling System) in an LMR (Liquid Metal Reactor). This model has been validated by comparisons of model predictions with experimental data from a large scale RVACS/RACS simulation experiment performed at Argonne National Laboratory. 4 refs., 1 fig.

Research Organization:
Argonne National Lab., IL (USA)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
6260134
Report Number(s):
CONF-871101-11; ON: DE87011375; TRN: 87-035095
Resource Relation:
Conference: California State Air Resources Board, Los Angeles, CA, USA, 15 Nov 1987
Country of Publication:
United States
Language:
English