skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Assessment of Tank 241-C-106 temperature response indications

Technical Report ·
DOI:https://doi.org/10.2172/61704· OSTI ID:61704

This report presents an assessment of waste tank 241-C-106 temperature response indications. The results are obtained through evaluation of historical data for FIC surface level data and temperature indication data from thermocouples in risers 8 and 14, contained in the SACS and TMACS databases. Computer analysis is used to augment observations and conclusions about hypothesized mechanisms present in the tank that could explain the data observations. From the historical temperature indications of risers 8 and 14 (neglecting the ventilation outages), several general observational conclusions are drawn that support hypotheses explaining more recently observed behavior.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
61704
Report Number(s):
PNL-10514; ON: DE95010425; TRN: 95:004263
Resource Relation:
Other Information: PBD: Mar 1995
Country of Publication:
United States
Language:
English