Calculation of MCPR (minimum critical power ratio) for BWR transients using the BNL plant analyzer
The critical power ratio (CPR) is used for determining the thermal limits of boiling water reactors. In this study, critical power ratios for a series of transients run on the Brookhaven Plant Analyzer (BPA) (1) have been calculated. The transients include nominal base case simulations, simulations with variations in relief valve setpoints and the number of failed feedwater heaters, simulations at the 100% power, 75% flow point on the extended load line of the MEOD, and a simulation with partial feedwater heating. The plant represented with the BPA is a BWR/4 rated at 3293 MW with a 6.38 m (251'') vessel. Data were obtained by the Plant Analyzer Development Group at BNL from a variety of sources describing the Browns Ferry Plant.
- Research Organization:
- Brookhaven National Lab., Upton, NY (USA); Nuclear Regulatory Commission, Washington, DC (USA)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 6156318
- Report Number(s):
- BNL-NUREG-39959; CONF-871101-36; ON: DE87012109; TRN: 87-035143
- Resource Relation:
- Conference: California State Air Resources Board, Los Angeles, CA, USA, 15 Nov 1987
- Country of Publication:
- United States
- Language:
- English
Similar Records
BWR stability analysis with the BNL Engineering Plant Analyzer
BWR stability analysis with the BNL Engineering Plant Analyzer
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
BWR TYPE REACTORS
TRANSIENTS
FAILURES
FEEDWATER
HEATING
REACTOR COMPONENTS
REACTOR SAFETY
REACTOR SIMULATORS
THERMAL ANALYSIS
ANALOG SYSTEMS
FUNCTIONAL MODELS
HYDROGEN COMPOUNDS
OXYGEN COMPOUNDS
REACTORS
SAFETY
SIMULATORS
WATER
WATER COOLED REACTORS
WATER MODERATED REACTORS
220900* - Nuclear Reactor Technology- Reactor Safety
210100 - Power Reactors
Nonbreeding
Light-Water Moderated