skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Calculation of MCPR (minimum critical power ratio) for BWR transients using the BNL plant analyzer

Conference ·
OSTI ID:6156318

The critical power ratio (CPR) is used for determining the thermal limits of boiling water reactors. In this study, critical power ratios for a series of transients run on the Brookhaven Plant Analyzer (BPA) (1) have been calculated. The transients include nominal base case simulations, simulations with variations in relief valve setpoints and the number of failed feedwater heaters, simulations at the 100% power, 75% flow point on the extended load line of the MEOD, and a simulation with partial feedwater heating. The plant represented with the BPA is a BWR/4 rated at 3293 MW with a 6.38 m (251'') vessel. Data were obtained by the Plant Analyzer Development Group at BNL from a variety of sources describing the Browns Ferry Plant.

Research Organization:
Brookhaven National Lab., Upton, NY (USA); Nuclear Regulatory Commission, Washington, DC (USA)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
6156318
Report Number(s):
BNL-NUREG-39959; CONF-871101-36; ON: DE87012109; TRN: 87-035143
Resource Relation:
Conference: California State Air Resources Board, Los Angeles, CA, USA, 15 Nov 1987
Country of Publication:
United States
Language:
English