Analysis of air-temperature measurements from the Three Mile Island Unit 2 reactor building
Abstract
The performance of the ambient air resistance temperature detectors (RTDs) just after the hydrogen burn in the TMI-2 Reactor Building is examined. The performance of the sensors is compared with physical models of the sensor/ambient air system. With one exception, the RTD data appear to be valid for the period examined. Based on the data, the hydrogen burn ended considerably before the first data points were recorded.
- Authors:
- Publication Date:
- Research Org.:
- EG and G Idaho, Inc., Idaho Falls, ID (United States)
- Sponsoring Org.:
- USDOE
- OSTI Identifier:
- 6138176
- Report Number(s):
- GEND-INF-030
ON: DE83011491
- DOE Contract Number:
- AC07-76ID01570
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: Portions are illegible in microfiche products
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 22 GENERAL STUDIES OF NUCLEAR REACTORS; 21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; THREE MILE ISLAND-2 REACTOR; REACTOR ACCIDENTS; REACTOR INSTRUMENTATION; COMBUSTION; HYDROGEN; PERFORMANCE; REACTOR SAFETY; TEMPERATURE GRADIENTS; THERMOMETERS; ACCIDENTS; CHEMICAL REACTIONS; ELEMENTS; ENRICHED URANIUM REACTORS; MEASURING INSTRUMENTS; NONMETALS; OXIDATION; POWER REACTORS; PWR TYPE REACTORS; REACTORS; SAFETY; THERMAL REACTORS; THERMOCHEMICAL PROCESSES; WATER COOLED REACTORS; WATER MODERATED REACTORS; 220900* - Nuclear Reactor Technology- Reactor Safety; 210200 - Power Reactors, Nonbreeding, Light-Water Moderated, Nonboiling Water Cooled
Citation Formats
Fryer, M O. Analysis of air-temperature measurements from the Three Mile Island Unit 2 reactor building. United States: N. p., 1983.
Web. doi:10.2172/6138176.
Fryer, M O. Analysis of air-temperature measurements from the Three Mile Island Unit 2 reactor building. United States. https://doi.org/10.2172/6138176
Fryer, M O. 1983.
"Analysis of air-temperature measurements from the Three Mile Island Unit 2 reactor building". United States. https://doi.org/10.2172/6138176. https://www.osti.gov/servlets/purl/6138176.
@article{osti_6138176,
title = {Analysis of air-temperature measurements from the Three Mile Island Unit 2 reactor building},
author = {Fryer, M O},
abstractNote = {The performance of the ambient air resistance temperature detectors (RTDs) just after the hydrogen burn in the TMI-2 Reactor Building is examined. The performance of the sensors is compared with physical models of the sensor/ambient air system. With one exception, the RTD data appear to be valid for the period examined. Based on the data, the hydrogen burn ended considerably before the first data points were recorded.},
doi = {10.2172/6138176},
url = {https://www.osti.gov/biblio/6138176},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Apr 01 00:00:00 EST 1983},
month = {Fri Apr 01 00:00:00 EST 1983}
}