The task is to measure the center line of the beam detector with respect to the magnetic centerline with a precision of +-0.2 mm; the measurement must be made on 250 magnets (they come in 6 lengths, from 25'' to 99'') by a technician. Optical, mechanical, and electrical techniques for carrying out this procedure were considered. An RF device operating at 53 MHZ was adopted for the following reasons: (a) it provides complete electrical checkout of the hardware at operating frequency, including the bidirectional operation of the pickup, (b) no mechanical contact with the strip lines is required, and (c) the demands of production measurements and maintenance of calibration are better matched to the skills of an average technician. We describe the conceptual design, fabrication, and performance of this device.