skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Evaluation of LLTR Series II test A-2 results. [Large Leak Test Rig]

Abstract

Series II Test A-2 employed a double-ended (DEG) tube rupture 122'' above the lower end of the LLTI shroud under typical evaporator startup conditions. The leak site was located 2'' below Spacer No. 4 at the same location as Test A-lb which employed nitrogen as the inert non-reactive injection fluid. The test yielded peak pressures of 375 psig in the leak site region and 485 psig at the upper tubesheet approximately 10 ms and 12 ms, respectively, after tube rupture. Higher peak temperatures (approx. 2200/sup 0/F) were measured in this test than during Series I sodium-water reaction testing (peak temperatures measured during Series were about 1900/sup 0/F maximum). These high peak temperatures occurred in Test A-2 long after the tube rupture (approx. 8 seconds) and did not contribute to the acoustic peak pressures produced in the first few milliseconds.

Authors:
; ; ; ;
Publication Date:
Research Org.:
General Electric Co., Sunnyvale, CA (USA). Advanced Reactor Systems Dept.
OSTI Identifier:
6082023
Report Number(s):
DOE/SF/70030-T31
ON: DE81024245; TRN: 82-000541
DOE Contract Number:  
AT03-76SF70030
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; 21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; CLINCH RIVER BREEDER REACTOR; STEAM GENERATORS; LEAKS; MOLTEN METAL-WATER REACTIONS; RELIEF VALVES; SODIUM; ALKALI METALS; BOILERS; BREEDER REACTORS; CONTROL EQUIPMENT; ELEMENTS; EPITHERMAL REACTORS; EQUIPMENT; FAST REACTORS; FBR TYPE REACTORS; FLOW REGULATORS; LIQUID METAL COOLED REACTORS; LMFBR TYPE REACTORS; METALS; POWER REACTORS; REACTORS; SODIUM COOLED REACTORS; VALVES; VAPOR GENERATORS; 220900* - Nuclear Reactor Technology- Reactor Safety; 210500 - Power Reactors, Breeding

Citation Formats

Whipple, J C, Shoopak, B F, Chen, K, Fan, C K, and Odegaard, T K. Evaluation of LLTR Series II test A-2 results. [Large Leak Test Rig]. United States: N. p., 1980. Web. doi:10.2172/6082023.
Whipple, J C, Shoopak, B F, Chen, K, Fan, C K, & Odegaard, T K. Evaluation of LLTR Series II test A-2 results. [Large Leak Test Rig]. United States. https://doi.org/10.2172/6082023
Whipple, J C, Shoopak, B F, Chen, K, Fan, C K, and Odegaard, T K. 1980. "Evaluation of LLTR Series II test A-2 results. [Large Leak Test Rig]". United States. https://doi.org/10.2172/6082023. https://www.osti.gov/servlets/purl/6082023.
@article{osti_6082023,
title = {Evaluation of LLTR Series II test A-2 results. [Large Leak Test Rig]},
author = {Whipple, J C and Shoopak, B F and Chen, K and Fan, C K and Odegaard, T K},
abstractNote = {Series II Test A-2 employed a double-ended (DEG) tube rupture 122'' above the lower end of the LLTI shroud under typical evaporator startup conditions. The leak site was located 2'' below Spacer No. 4 at the same location as Test A-lb which employed nitrogen as the inert non-reactive injection fluid. The test yielded peak pressures of 375 psig in the leak site region and 485 psig at the upper tubesheet approximately 10 ms and 12 ms, respectively, after tube rupture. Higher peak temperatures (approx. 2200/sup 0/F) were measured in this test than during Series I sodium-water reaction testing (peak temperatures measured during Series were about 1900/sup 0/F maximum). These high peak temperatures occurred in Test A-2 long after the tube rupture (approx. 8 seconds) and did not contribute to the acoustic peak pressures produced in the first few milliseconds.},
doi = {10.2172/6082023},
url = {https://www.osti.gov/biblio/6082023}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Jul 01 00:00:00 EDT 1980},
month = {Tue Jul 01 00:00:00 EDT 1980}
}